{"created":"2023-05-15T10:20:05.188402+00:00","id":278,"links":{},"metadata":{"_buckets":{"deposit":"f2cf60b6-4b35-43c5-8eef-4434ddc033f7"},"_deposit":{"created_by":17,"id":"278","owners":[17],"pid":{"revision_id":0,"type":"depid","value":"278"},"status":"published"},"_oai":{"id":"oai:cit.repo.nii.ac.jp:00000278","sets":["89"]},"author_link":[],"control_number":"278","item_1712121387387":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_ab4af688f83e57aa","subitem_version_type":"AM"}]},"item_4_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2019-06-05","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"6","bibliographicVolumeNumber":"9","bibliographic_titles":[{"bibliographic_title":"Buildings","bibliographic_titleLang":"en"}]}]},"item_4_full_name_2":{"attribute_name":"著者","attribute_value_mlt":[{"names":[{"name":"藤井 賢志","nameLang":"ja"}]}]},"item_4_full_name_3":{"attribute_name":"著者(英)","attribute_value_mlt":[{"names":[{"name":"Fujii, Kenji","nameLang":"en"}]}]},"item_4_select_20":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_select_item":"author"}]},"item_4_text_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_text_value":"https://doi.org/10.3390/buildings9060140"}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2019-06-20"}],"displaytype":"detail","filename":"buildings-09-00140-v4.pdf","filesize":[{"value":"16.8 MB"}],"format":"application/pdf","license_note":"Creative Commons\nAttribution 4.0 International (CC BY 4.0)\n(https://creativecommons.org/licenses/by/4.0/)","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"Pushover-Based Seismic Capacity Evaluation of Uto City Hall Damaged by the 2016 Kumamoto Earthquake","objectType":"fulltext","url":"https://cit.repo.nii.ac.jp/record/278/files/buildings-09-00140-v4.pdf"},"version_id":"c561dc66-0338-472a-8c38-f9f5f49ecb3e"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"existing building; structural irregularity"},{"subitem_subject":"pushover analysis"},{"subitem_subject":"bidirectional excitation"},{"subitem_subject":"seismic capacity evaluation"},{"subitem_subject":"torsion"},{"subitem_subject":"existing building; structural irregularity"},{"subitem_subject":"pushover analysis"},{"subitem_subject":"bidirectional excitation"},{"subitem_subject":"seismic capacity evaluation"},{"subitem_subject":"torsion"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Pushover-Based Seismic Capacity Evaluation of Uto City Hall Damaged by the 2016 Kumamoto Earthquake","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Pushover-Based Seismic Capacity Evaluation of Uto City Hall Damaged by the 2016 Kumamoto Earthquake","subitem_title_language":"en"}]},"item_type_id":"4","owner":"17","path":["89"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2019-06-20"},"publish_date":"2019-06-20","publish_status":"0","recid":"278","relation_version_is_last":true,"title":["Pushover-Based Seismic Capacity Evaluation of Uto City Hall Damaged by the 2016 Kumamoto Earthquake"],"weko_creator_id":"17","weko_shared_id":-1},"updated":"2024-04-03T05:29:15.951477+00:00"}